top of page

Lambda Exadiodic + Monodiodic—High Intensity Dual Handpiece Laser Therapy System

SKU LMB002

Lambda 2 Exadiodic + Monodiodic (LMB002) — High Intensity Dual Handpiece System

The Lambda 2 is the most powerful and clinically versatile variant in the Lambda range — combining an exadiodic handpiece (six 30W pulsed laser diodes, 180W total) with a monodiodic handpiece (single 30W diode) in a dual-output system with independent channel management.

The Exadiodic Handpiece — Up to 180W Pulsed The exadiodic handpiece's six-diode array delivers up to 180W of peak pulsed power across a 905nm emission — the highest-power HILT output in the Lambda range. The multi-diode geometry provides a broader treatment beam footprint compared to the monodiodic single-point emission, enabling faster coverage of larger treatment areas (quadriceps, hamstrings, lumbar muscles, shoulder girdle) without the prolonged point-by-point technique required with single-diode devices. The 180W pulsed power enables high energy dose delivery within short pulse durations — maximising therapeutic effect while maintaining safe average power through controlled pulse width and frequency.

The Monodiodic Handpiece — Up to 30W Pulsed The monodiodic handpiece provides focused single-point 905nm delivery for targeted treatment of specific anatomical structures — individual trigger points, tendon insertion sites, small joint periarticular tissue, and nerve point therapy. The precision of single-diode focused emission is clinically important for accurate dosimetry at specific tissue targets.

Independent Dual Handpiece Management Lambda 2's most distinctive clinical feature is its ability to manage both handpieces simultaneously and independently — allowing the operator to use the exadiodic handpiece for broad muscle area treatment while the monodiodic is applied to a specific trigger point or tendon in the same session, or to configure different protocols for sequential application without reconfiguring the unit between handpiece changes.

Output frequency: 0.5 to 10,000 Hz Handpiece wavelength: 905 nm Output pulse length: 100 nanoseconds Max power (Exadiodic): Up to 180W pulsed Max power (Monodiodic): Up to 30W pulsed Electrical input power: 25 VA Weight: 3.5 Kg

 

High-Luminosity Graphic Touchscreen Display The same high-brightness colour touchscreen found across the Physioled range — providing clear parameter visualization, real-time treatment monitoring, and intuitive icon-based navigation.

Automatic Frequency Scanning Lambda automatically scans and applies the delivered frequency across the therapeutic window during treatment — ensuring optimal frequency-tissue interaction without requiring manual frequency optimization by the clinician during the session.

Joule Delivery Visualization Lambda displays the total energy delivered (in Joules) throughout and at the conclusion of each treatment session — providing precise dosimetric documentation that is essential for evidence-based laser therapy, patient record-keeping, and inter-session treatment consistency. Few competitive laser units in this class offer real-time and cumulative Joule display.

Warning Signal on Handpiece During Emission A visual warning indicator on the handpiece itself activates during laser energy delivery — providing an immediate, local safety cue at the treatment site that confirms active emission and serves as a safety reminder for operator hand positioning and patient eye protection compliance.

Automatic Accessory Recognition Lambda automatically recognizes the connected handpiece type — preventing accidental application of incorrect emission parameters for a given handpiece configuration and eliminating manual accessory selection steps.

Wide Range of Preset Protocols + Custom Programs Extensive factory-stored protocols covering the most common laser physiotherapy applications — organised by pathology, tissue depth, and acute/chronic presentation — with full custom program capability for experienced practitioners.

USB Port Upgrade Capability Firmware and protocol library updates deliverable via USB throughout the unit's clinical lifetime.

Security Control — Automatic Emission Disable on Incorrect Handpiece Position Lambda includes an automatic safety control that disables laser emission if the handpiece is not correctly positioned or if a handpiece attachment error is detected — preventing accidental uncontrolled emission and protecting both patient and operator.

Quantity

Technical Specifications

Specification

Lambda 2 (LMB002)

Wavelength

905 nm

Aiming beam

Max power (monodiodic)

30W pulsed

Max power (exadiodic)

180W pulsed

Max power (YAG)

Output frequency

0.5–10,000 Hz

Pulse length

100 nsec

Emission modes

Pulsed

Laser class

Handpieces

2 (exadiodic + monodiodic)

Independent handpiece management

Yes

Power supply

90–240 Vac / 50–60 Hz

Electrical input power

25 VA

Joule visualization

Yes

Auto frequency scanning

Yes

Auto accessory recognition

Yes

Preset protocols

Yes

Custom programs

Yes

USB upgrade

Yes

Remote interlock

Yes

Weight

3.5 Kg

Dimensions

390 × 315 × 170 mm

Certifications

CE 0051, IMQ, CISQ, IQNet

Origin

Made in Italy

Loading…
bottom of page